PANTHER
DHW heating using through-flow technology
-
- Electric spark ignition
- Large LCD
- Equithermal regulation
-
Downloads
Productoverview
Elegance and harmony in your interior
The Panther gas boiler line allows for boiler control according to outside temperature. This concerns so-called equithermal regulation. By installing an outside sensor and setting the parameters on the boiler display, you can regulate the temperature of the heating system water according to the current outside temperature. If an eBus room thermostat has been connected, these parameters can be set directly with that.
Specifications for PANTHER 25 KOV, PANTHER 25 KTV, PANTHER 30 KTV boilers:- Boilers designed with DHW heating using through-flow technology and the KOMFORT function for quickly heating DHW
- Individual dimensions: 740 x 410 x 311 mm
- 2 output levels 25 kW or 30 kW
- A new water component group with more easily accessible parts simplifies maintenance.
- Clear LCD
- The controls are based on the principle of "one button = one function"
- Common electronics on all boilers with eBus protocol
- Equithermal boiler regulation with an eBus controller and outside temperature sensor
- The boilers can be installed on a connection platform that is sold as an accessory.
- Wall hung design with combustion gases exhausted to the chimney (KOV) or as a turbo version (KTV)
Technical parameters
-
Description
Gas ategory II2H3P II2H3P II2H3P Version C12, C32, C42, C52, C82 B11BS C12, C32, C42, C52, C82 Ignition electonical electonical electonical 30 KTV 25 KOV 25 KTV -
Output / Fuel
Fuel natural gas: propane natural gas: propane natural gas: propane Maximum heat input (kW) 32,5 26,8 26,5 Minimum heat input (kW) 12,2 9,9 10,6 Maximum heat output (kW) 29,6 24,6 24,6 Minimum heat output (kW) 10,4 8,4 8,9 Efficiency (%) 91,1 91,8 92,8 Maximum gas consumption (m3 / h) natural gas: 3,44 natural gas: 2,84 natural gas: 2,80 Minimum gas consumption (m3 / h) natural gas: 1,29 natural gas: 1,05 natural gas: 1,12 Gas flow at maximum power in hot water mode (m3 / h) Maximum gas consumption ( kg/h) propane: 2,52 propane: 2,08 propane: 2,05 Minimum gas consumption (kg/h) propane: 0,95 propane: 0,77 propane: 0,82 NOx class 3 3 3 Max. heat output at 80/60 ° C (kW) Min. heat output at 80/60 ° C (kW) Max. heat output at 50/30 ° C (kW) Min. heat output at 50/30 ° C (kW) The effeciency at the temperature gradient 80/60 ° C (%) Degree of utilization at the temperature gradient 80/60 ° C (%) Degree of utilization at part load PCI at 40/30 ° C (30%) Output 1st output level (kW) Output 2nd output level (kW) Nominal input first output level (kW) Nominal input second output level (kW) Consumption first output level (m3/hr) Consumption second output level (m3/hr) Consumption first output level (kg / hr) Consumption second output level (kg / hr) The degree of utilization according to European directive 92/42 30 KTV 25 KOV 25 KTV -
Gas pressure
Supply pressure (mbar) natural gas: 20, propane: 37 natural gas: 20, propane: 37 natural gas: 20, propane: 37 Diameter of gas valve restrictor (mm) natural gas: 6,90, propane: 7,30 natural gas: 6,10, propane: 5,20 natural gas: 5,80, propane: 5,95 Max. burner pressure (mbar) natural gas: 13,0, propane: 35,5 natural gas: 13,0, propane: 31,30 natural gas: 12,4, propane: 32,7 Min. burner pressure (mbar) natural gas:1,7, propane: 4,8 natural gas: 2,1, propane: 4,6 natural gas: 1,9, propane: 5,0 Injector diameter (mm) natural gas: 1,20, propane: 0,73 natural gas: 1,20, propane: 0,73 natural gas: 1,20, propane: 0,73 30 KTV 25 KOV 25 KTV -
Heating
Max. operating pressure (bar) 3 3 3 Min. operating pressure (bar) 0,5 0,5 0,5 Recommended operating pressure (bar) 1,2 -2 1,2 -2 1,2 -2 Test water pressure (bar) Max. working temperature (° C) 80 80 80 Temperature range (°C) 38-80 38-80 38-80 Expansion vessel (l) 8 7 7 Water volume of the boiler body (l) Volume of boiler (amount of HW) (l) Max. pressure in expansion vessel (bar) 3 3 3 Number of CI blocks of boilers body (ks) Number of burner tubes (pcs) Gas connection G 1/2 G 1/2 G 1/2 Heating water connection G 3/4 G 3/4 G 3/4 Pressure loss at ?t 20 °C (Pa) Safety valve maximum operating pressure (bar) 3 3 3 30 KTV 25 KOV 25 KTV -
Domestic hot water (HW)
Max. supply pressure (bar) 10 10 10 Min. supply pressure (bar) 0,5 0,5 0,5 Min. flow HW (l/min) 1,7 1,7 1,7 Flow rate at ?T 30°C (l/min) 14 12,1 12,1 Temperature range (°C) 38-60 38-60 38-60 The size of cold water flow restrictor (l / min) 12 10 10 Volume of tank (l) Amount of received HW (according to EN 625) (l / min) Safety valve HW, maximum operating pressure (bar) Expansion vessel HW (l) 30 KTV 25 KOV 25 KTV -
Electrical data
Voltage / Frequency (V/Hz) 230/50 230/50 230/50 Input (W) 152 92 147 Protection class IPX4 IPX4D IPX4D Current (A) 0,66 0,4 0,65 Electrical classification 30 KTV 25 KOV 25 KTV -
Extraction of combustion gases
Method fan flue open flue fan flue Max. length of concentric flue ? 60/100 (Em) 4 - 4,5 Max. length of concentric flue ? 80/125 (Em) 8 - 12 Max. length of separate flue ? 80 + 80 (Em) 15+15 - 15+15 Flue diameter (mm) 60/100,80/125,80/80 125 60/100,80/125,80/80 Flue gas temperature (° C) 147 108 122 Flue gas mass flow rate max. (g/s) 19,5 19,6 13,4 Noise level at max. output (dB (A)) <50 <50 <50 The flow of fresh air (1013 mbar - 0 ° C) (m3 / h) Flue gas mass flow at max. output (g / s) Flue gas mass flow at minimum output (g / s) Flue gas mass flow under warm water (g / s) Flue gas temperature at max. output and gradient 80/60 °C (° C) Flue gas temperature at max. output and gradient 50/30 ° C (° C) Flue gas temperature at min. output and gradient 80/60 °C (° C) Flue gas temperature at min. output and gradient 50/30 ° C (° C) Flue gas temperature at overheating (° C) Flue gas temperature in hot water mode (° C) Min. required stable chimney draft (Pa) 30 KTV 25 KOV 25 KTV -
Dimensions
height / width / depth (mm) 807 / 450 / 360 742 / 410 / 311 742 / 410 / 311 Weight excluding water (kg) 39 35 37 Number CE 30 KTV 25 KOV 25 KTV -
Values ??of flue gases
Measured at nominal heat output and the reference gas G20 in heating mode 30 KTV 25 KOV 25 KTV CO (ppm) CO (mg / kWh) CO2 (%) Weighted amount of NOx (ppm) Weighted amount of NOx (mg / kWh)
Download
Filename Download file Declaration of conformity Panther PDF (735 KB) User manual Panther PDF (1 MB)